triton t80 easi fit manual

Welcome to the Triton T80 Easi-Fit manual, your comprehensive guide to installing, operating, and maintaining your electric shower. This manual ensures safe and optimal use, covering essential features, installation steps, and troubleshooting tips for a seamless experience.

Purpose and Scope of the Manual

The purpose of this manual is to provide clear, detailed guidance for the safe installation, operation, and maintenance of the Triton T80 Easi-Fit electric shower. It is designed to ensure optimal performance and longevity of the product while adhering to safety standards. The scope includes essential information for installers, homeowners, and service engineers, covering technical specifications, troubleshooting, and compliance with regulations. This manual is structured to address all aspects of the shower system, from pre-installation checks to routine maintenance, ensuring users can operate the shower confidently and safely. By following the instructions, users can avoid potential risks and enjoy a reliable, high-quality showering experience.

Important Safety Information

Ensure the shower is installed, used, and maintained following the instructions to avoid risks. Always isolate electrical and water supplies before installation or maintenance. Read all instructions thoroughly and retain them for future reference. Avoid taking risks with plumbing or electrical connections. WARNING: Do not operate the shower if frozen or damaged. Keep the showerhead away from direct body contact to prevent scalding. Supervise children and vulnerable individuals during use. Regularly clean the showerhead to prevent scale buildup, which can cause temperature issues. Do not restrict water flow or use damaged hoses. If water stops during use, turn off the supply immediately. Adhere to all safety guidelines to ensure safe and reliable operation.

Key Features of the Triton T80 Easi-Fit Shower

The Triton T80 Easi-Fit Shower is designed for ease of installation and optimal performance. It features Dura-Flow technology for consistent water flow and temperature control, ensuring a reliable showering experience. The showerhead is equipped with multiple spray settings for versatility. Its compact design allows for easy wall mounting, fitting seamlessly into various bathroom layouts. The unit includes a stabiliser valve to minimise temperature fluctuations caused by changes in water pressure. Additional features such as thermal cut-out and pressure relief devices enhance safety. The T80 Easi-Fit is also designed with energy efficiency in mind, providing cost-effective operation without compromising on performance. Its durable construction ensures long-lasting reliability, making it a practical choice for both new installations and replacements.

Installation Requirements

The Triton T80 Easi-Fit Shower requires compliance with BS 7671 electrical standards and BS EN 806 plumbing regulations. Installation must be performed by a qualified professional, ensuring proper wall mounting, water supply connections, and electrical safety. The unit must not be sealed with silicone, and all vents must remain unobstructed for optimal performance and safety.

Pre-Installation Checklist

Before installing the Triton T80 Easi-Fit Shower, ensure the following steps are completed:

  • Verify that the water supply meets the required pressure and flow rate specifications.
  • Check that the electrical supply complies with the shower’s power ratings and safety standards.
  • Ensure the wall where the shower will be mounted is sturdy and level.
  • Confirm that all cable and water entry points align with the shower unit’s connections.
  • Flush the water supply pipes to remove any debris before connecting to the shower.
  • Ensure a 30mA RCD is installed in the electrical circuit for safety.
  • Review and adhere to all safety guidelines and installation instructions.

Completing this checklist ensures a safe and efficient installation process.

Plumbing Requirements

The plumbing installation for the Triton T80 Easi-Fit Shower must comply with Water Regulations and Building Regulations, adhering to BS EN 806 standards. The supply pipe should be flushed to remove debris before connecting to the shower unit. Avoid soldering pipes or fittings within 300mm of the unit to prevent heat damage. Ensure all connections are secure, but avoid using excessive force, as finger-tight connections are sufficient. Do not fit any flow control devices, as the outlet acts as a vent for the heater. The shower must not be connected to the inlet supply via a hose-set. Proper plumbing ensures safe and efficient operation of the shower. Always follow the manufacturer’s guidelines for a trouble-free installation.

Electrical Requirements

The installation of the Triton T80 Easi-Fit Shower must comply with BS 7671 (IEE Wiring Regulations) and local electrical standards. The appliance must be earthed, and all electrical connections should be tight to prevent overheating. A 30mA residual current device (RCD) is mandatory for UK installations. The shower is designed for permanent connection to the electrical mains system and should not be connected to temporary or shared circuits. Ensure no other electrical devices, such as pumps or fans, are connected to the shower’s circuit. Regular inspections by a qualified electrician, at least every two years, are recommended to ensure safety and performance. Always follow the manufacturer’s guidelines for electrical installations to avoid risks and ensure compliance with safety standards.

Siting and Wall Mounting Guidelines

The Triton T80 Easi-Fit Shower must be mounted on a finished wall surface, ensuring it is level and secure. Do not tile up to or seal around any part of the unit using silicone sealer, as this could block essential PRD (Pressure Relief Device) vents. Ensure the water and cable entry points align with your plumbing and electrical connections. The unit should be positioned to allow easy access for maintenance and servicing; Avoid installing the shower in areas exposed to extreme temperatures or where it may be susceptible to freezing. Use a spirit level to ensure accurate fitting and prevent water retention. If installing in hard water areas, consider consulting Triton’s guidelines for additional recommendations. Always ensure the unit is mounted firmly to withstand regular use and maintain stability over time. Annual inspections are recommended to verify the wall mounting remains secure.

Installation Process

  1. Fitting the shower unit to the wall securely.
  2. Connecting water and electrical supplies carefully.
  3. Installing the shower head and hose properly.
  4. Performing final checks and commissioning the unit.

Step-by-Step Installation Instructions

  1. Ensure the site is prepared, and all pre-installation checks are completed.
  2. Isolate water and electrical supplies before starting the installation.
  3. Mount the shower unit to the wall using suitable fixings for your wall type.
  4. Connect the water supply pipes, ensuring they are flushed and free from debris.
  5. Install the electrical connections, adhering to safety standards and regulations.
  6. Fitting the shower head and hose securely to the unit.
  7. Fit the cover and ensure all vents are unobstructed for proper function.
  8. Follow the commissioning procedure to fill and test the unit.
  9. Perform final checks to ensure correct operation and safety.

These steps ensure a safe and proper installation of your Triton T80 Easi-Fit shower.

Connecting Water and Electrical Supplies

  • Ensure water pipes are flushed to remove debris before connecting to the shower unit.
  • Avoid soldering pipes within 300mm of the unit to prevent heat damage.
  • Connect the water supply, ensuring compatibility with the unit’s entry points.
  • Install a scale inhibitor if operating in hard water areas (above 200 ppm).
  • Ensure electrical connections comply with BS 7671 and include a 30mA RCD.
  • Tighten all electrical connections to prevent overheating and ensure safety.
  • Do not connect other electrical devices to the shower’s circuit.

These steps ensure safe and proper connections for optimal performance.

Fitting the Shower Unit to the Wall

To fit the shower unit to the wall, ensure the wall surface is flat, dry, and finished (e.g., tiled). The unit must be mounted on top of the tiles and not sealed with silicone after installation. Avoid blocking or sealing any PRD (Pressure Relief Device) vents on the unit, as this could compromise safety. Carefully align the unit with the wall brackets and secure it firmly to ensure stability. Use the provided fixings to prevent movement during use. Ensure the unit is level to maintain proper function and appearance. After fitting, connect the water and electrical supplies as detailed in the manual. Proper wall mounting is crucial for safe and reliable operation of the shower.

Installing the Shower Head and Hose

Begin by attaching the shower hose to the outlet on the shower unit. Ensure the connection is finger-tight to avoid damaging the threads. Next, screw the shower head onto the other end of the hose, making sure it is securely fitted. Do not use excessive force, as this could damage the components. Once installed, check for any leaks by gently turning on the water supply. If leaks are detected, tighten the connections slightly. Finally, test the shower head and hose by running water through them to ensure proper flow and function. Regular cleaning of the shower head with a descaler will prevent mineral buildup and maintain optimal performance. Proper installation ensures a reliable and enjoyable showering experience.

Final Checks and Commissioning

Before commissioning the shower, ensure all connections are secure and isolate the electrical and water supplies. Check for any leaks at joints and connections. Fill the unit with water by turning on the supply and allowing it to flow through the shower head. Once filled, switch on the heating elements to test the temperature control and flow rate. Ensure the unit operates smoothly and adjust settings as needed. Verify that the PRD (Pressure Relief Device) is functioning correctly and that all safety features are active. Finally, familiarize yourself with the operating instructions and ensure the shower is ready for safe and efficient use. Proper commissioning ensures optimal performance and longevity of the unit.

Operating the Shower

Understand and adjust the temperature and flow rate using the intuitive controls. Ensure safe usage by following guidelines and maintaining proper water flow for optimal performance and efficiency.

Understanding the Controls and Settings

The Triton T80 Easi-Fit shower features user-friendly controls designed for easy operation. The temperature control dial allows you to set your preferred water temperature, while the flow rate can be adjusted to optimize water usage. The showerhead includes multiple spray settings, providing a customizable experience. A stabilizer valve minimizes temperature fluctuations caused by changes in water pressure. For safety, the shower automatically cuts off if water flow is interrupted or if the unit overheats. Familiarizing yourself with these controls ensures a safe and enjoyable showering experience. Regular cleaning of the showerhead and filter is recommended to maintain optimal performance and prevent mineral buildup.

Adjusting Temperature and Flow Rate

The Triton T80 Easi-Fit shower allows for precise temperature and flow rate adjustments to suit your preferences. The temperature control dial is located on the front of the unit and can be turned clockwise or counterclockwise to increase or decrease the water temperature. The flow rate can be adjusted using the separate flow control lever, which regulates water volume. For optimal performance, ensure the water supply meets the minimum pressure requirements. During colder months, you may need to adjust the temperature setting slightly higher due to lower mains water temperatures. Regularly cleaning the showerhead and filter will help maintain consistent flow and temperature. Always refer to the manual for specific guidance on adjusting these settings safely and effectively.

Safe Usage Tips

Ensure the shower is installed by a qualified professional to meet safety standards. Avoid using the shower if it’s frozen or damaged, and never restrict water flow by placing the showerhead against your body. Be cautious when restarting the shower immediately after stopping, as a surge of hot water may occur. Keep the unit clean and avoid placing items like soap bottles on top, as liquids could seep inside. Regularly descale the showerhead to maintain performance and prevent scale buildup, which can affect temperature control. Always follow the manufacturer’s guidelines for safe operation and maintenance to ensure a safe and enjoyable showering experience.

Maintenance and Care

Regular maintenance ensures optimal performance. Clean the shower with warm, soapy water and descale regularly to prevent mineral buildup. Avoid harsh chemicals and follow manufacturer guidelines.

Cleaning the Shower Unit

Regular cleaning is essential to maintain the Triton T80 Easi-Fit shower’s performance and longevity. Use warm, soapy water to clean the unit, avoiding harsh chemicals that may damage the finish. Pay particular attention to the showerhead and hose, ensuring they are free from limescale and debris. For descaling, apply a suitable descaling solution and rinse thoroughly. Do not use abrasive materials or scrubbers, as they may scratch the surfaces. After cleaning, dry the unit to prevent water spots. Additionally, ensure the PRD vents are not blocked to maintain proper function. Regular maintenance will keep your shower running efficiently and ensure optimal water flow and temperature control.

Descaling and Removing Mineral Deposits

Regular descaling is crucial for maintaining the Triton T80 Easi-Fit shower’s efficiency, especially in hard water areas. Use a suitable descaling solution to remove mineral deposits, following the product’s instructions. Apply the solution to the showerhead and hose, ensuring all scale is dissolved. Rinse thoroughly with clean water to remove any residue. For severe scaling, repeat the process if necessary. Always avoid using abrasive materials or harsh chemicals, as they may damage the unit’s surfaces. Additionally, ensure the PRD (Pressure Relief Device) vents are not blocked by scale buildup. Regular descaling will prevent reduced water flow and maintain optimal temperature control. For heavy mineral buildup, consider professional servicing every two years to ensure peak performance.

Replacing Parts and Servicing

Regular servicing and part replacement are essential to maintain the Triton T80 Easi-Fit shower’s performance and longevity. Always use genuine Triton parts to ensure compatibility and safety. If a part is damaged or worn, replace it promptly to avoid further issues. The showerhead, hose, and seals are common components that may need replacement due to mineral buildup or wear. For complex repairs, contact a qualified technician or Triton service engineer. Additionally, check and clean the PRD (Pressure Relief Device) vents regularly to ensure proper function. For hard water areas, consider professional servicing every two years to address mineral deposits. Refer to the spare parts section for details on compatible replacements; Always follow Triton’s guidelines to avoid voiding the warranty or causing damage.

Troubleshooting Common Issues

Identify and resolve common faults, such as temperature fluctuations or low water flow, using diagnostic tips and guidelines provided in this section for optimal shower performance.

Fault Finding and Diagnostic Tips

Identify common issues with your Triton T80 Easi-Fit shower by checking for blockages in the showerhead or hose, which can cause low water flow. Ensure electrical connections are secure and meet safety standards. If temperature fluctuations occur, inspect the temperature control dial or check for scale buildup. For persistent issues, refer to the manual for specific error codes and solutions. Always isolate water and electrical supplies before attempting repairs. If problems persist, consult a qualified engineer. Regular maintenance, such as descaling, can prevent many issues. Use diagnostic guides to pinpoint faults and ensure optimal performance.

  • Check for blockages in the showerhead or hose.
  • Verify electrical connections are secure and meet safety standards.
  • Inspect the temperature control dial for proper function.
  • Check for scale buildup and descale if necessary.

Resolving Common Problems

Addressing issues with your Triton T80 Easi-Fit shower often involves simple fixes. For low water flow, descale the showerhead or check for kinked hoses. If the shower doesn’t heat water, ensure the power is on and the temperature setting is correct. Reset the unit if it overheats by turning it off and letting it cool. For leaks, tighten connections or replace worn seals. Always refer to the manual for detailed solutions. Regular maintenance, like cleaning filters, can prevent many problems. If issues persist, contact a professional. By following these steps, you can quickly resolve common issues and ensure your shower operates efficiently.

  • Descale the showerhead to improve water flow.
  • Check for kinked hoses or blockages.
  • Ensure the power is on and settings are correct.
  • Reset the unit if it overheats;

Advanced Troubleshooting Techniques

For more complex issues with your Triton T80 Easi-Fit shower, advanced troubleshooting techniques can help resolve them effectively. Start by checking the PRD (Pressure Relief Device) for blockages or damage, as this can cause unexpected shutdowns. Inspect electrical connections for tightness and ensure no signs of overheating or corrosion. If temperature fluctuations occur, verify the stabilizer valve is functioning correctly. For persistent issues, perform a factory reset by turning off the power, waiting 30 seconds, and restarting. If problems remain, consult a qualified engineer. Regularly inspecting internal components and ensuring proper water flow can prevent many advanced issues from arising. Always follow safety guidelines during these procedures.

  1. Check the PRD for blockages or damage.
  2. Inspect electrical connections for tightness and signs of wear.
  3. Verify the stabilizer valve’s functionality.
  4. Perform a factory reset if issues persist.

Technical Specifications

The Triton T80 Easi-Fit is available in 8.5kW, 9.5kW, and 10.5kW models, ensuring compatibility with various electrical systems. It features Dura-Flow technology for extended durability and includes multiple cable and water entry points for flexible installation. The unit complies with safety standards like BS 7671 and is designed for easy maintenance and repair.

  • Power ratings: 8.5kW, 9.5kW, 10.5kW.
  • Cable and water entry points for installation flexibility.
  • Complies with BS 7671 and safety regulations.

Dimensions and Cable/Water Entry Points

The Triton T80 Easi-Fit shower unit has dimensions designed for standard bathroom installations, ensuring compatibility with most wall types. The unit features multiple cable and water entry points, located at the bottom, top, and rear, offering flexibility during installation. These entry points allow for easy connection to water supplies and electrical systems, reducing installation complexity. The shower head and hose connections are also strategically positioned for convenient access. All entry points are sealed to prevent water ingress, ensuring long-term durability. These specifications ensure the unit fits seamlessly into various bathroom layouts while maintaining safety and functionality.

  • Dimensions: Compact design for easy wall mounting.
  • Cable entry points: Multiple locations for flexible installation.
  • Water entry points: Durable and leak-resistant connections.

Electrical and Plumbing Specifications

The Triton T80 Easi-Fit shower is available in 8.5kW, 9.5kW, and 10.5kW models, ensuring compatibility with various electrical systems. It requires a 30mA RCD for safe operation and must be earthed to meet safety standards. The shower is designed to connect to a permanent electrical supply, adhering to BS 7671 wiring regulations. For plumbing, the unit must be installed in accordance with Water Regulations and BS EN 806. The supply pipes should be flushed before connection, and soldering within 300mm of the unit is prohibited. The shower is not suitable for connection via a hose-set, ensuring reliable and safe water supply. Regular descaling is recommended for optimal performance, especially in hard water areas.

  • Power ratings: 8.5kW, 9.5kW, and 10.5kW.
  • Electrical requirements: 30mA RCD and earthing mandatory.
  • Plumbing compliance: BS EN 806 and Water Regulations.
  • Descaling recommended for hard water areas.

Compliance with Safety Standards

The Triton T80 Easi-Fit shower adheres to stringent safety standards, ensuring safe operation and user protection. It is designed to meet EC Registered Design requirements and holds patents pending, including GB 2489547 and GB 2495343. The shower complies with BS 7671 for electrical installations and BS EN 806 for plumbing. A 30mA RCD is mandatory for electrical safety, and the unit must be earthed to prevent hazards. The shower is also equipped with a Pressure Relief Device (PRD) to manage water pressure safely. Regular maintenance, such as descaling and filter cleaning, is recommended to maintain compliance and performance. These measures ensure the shower operates reliably and safely under normal conditions.

  • Meets EC Registered Design and pending patents.
  • Complies with BS 7671 and BS EN 806 standards.
  • 30mA RCD and earthing required for safety.
  • Equipped with a Pressure Relief Device (PRD).

Additional Resources

For further assistance, Triton offers customer support, online videos, and warranty information. Visit their official website for detailed guides, troubleshooting tips, and service options.

  • Customer Support: Contact for inquiries and spare parts.
  • Online Videos: Watch tutorials for installation and maintenance.
  • Warranty: Check details for coverage and service options.

Customer Support and Service Information

Triton provides comprehensive customer support and service resources to ensure optimal use of your T80 Easi-Fit shower. For inquiries, spare parts, or technical assistance, contact their Customer Service team directly. Online, you can access installation guides, troubleshooting tips, and video tutorials. Service engineers are available for professional installations and repairs, ensuring compliance with safety standards. Visit Triton’s official website for detailed support options, including warranty information and maintenance advice. Always refer to the provided installation guide for specific product requirements and safety guidelines. Triton’s dedicated support team is committed to resolving issues promptly and ensuring your shower operates efficiently. Regular servicing is recommended to maintain performance and longevity.

Online Videos and Tutorials

Triton offers a range of online videos and tutorials to assist with the installation, operation, and maintenance of the T80 Easi-Fit shower. These resources provide step-by-step guidance and practical tips, helping users understand key features and troubleshooting techniques. While the videos may not always feature the exact model, they cover general electric shower basics and installation best practices. Visit Triton’s official website to access these tutorials, which are designed to complement the manual and enhance your overall experience. Watching these videos before starting the installation can help ensure a smooth and successful process. They are an invaluable resource for both new and experienced users.

Warranty and Spare Parts Information

The Triton T80 Easi-Fit shower is backed by a comprehensive warranty, ensuring coverage for parts and labor under normal use. For specific terms and conditions, refer to the warranty section in this manual or contact Triton’s Customer Service. Spare parts, including showerheads, hoses, and internal components, can be purchased through Triton’s Spares Department or authorized retailers. Regular maintenance, such as descaling and cleaning, is essential to maintain warranty validity. For any inquiries or to order spare parts, visit Triton’s official website or contact their support team. Always ensure genuine Triton parts are used to uphold safety and performance standards.

Leave a Reply